Line-interactive UPS EASYLINE 650 with AVR voltage regulation
While the mains voltage is in range, the AVR UPS EVER EASYLINE 650 AVR USB runs from the mains, filtering the voltage and raising or lowering it as needed. If the mains fails or the frequency drifts, the unit switches to battery in under 6 ms. On battery, the output is a stepped sine wave.
The battery lasts 8 minutes at 50% load and 2 minutes at 80% load. After an 80% discharge, the UPS recharges the battery to 90% within 6 hours. With a load below 40 W or nothing connected, the UPS switches itself off on battery to avoid deep discharge.
Display, connections and alarms
The front has a power button, an LCD display and a USB-B port for the computer connection. The LCD shows load and battery level on a four-step scale, plus input and output voltage with frequency. The RJ11 telephone filter protects the phone line and modem against surges. The fixed power cord has an earthed plug that fits both type E and type F sockets.
On battery, the UPS beeps briefly every 10 seconds, every second when the battery is low and every half second on overload. The UPS restarts by itself when mains power returns, and cold start lets you switch it on without mains power. On a computer connected over USB, PowerSoft Professional monitors the UPS and shuts the system down automatically when needed.
Installation and first start
Keep at least 20 cm of free space around the UPS, and the earthed socket must be no more than 1.5 m away; do not use an extension lead. If the UPS has been brought in from the cold, wait at least 2 hours before installing it. In normal use the load must not exceed 80% of the rated power.
- Plug the UPS in and let the battery charge for at least 6 hours.
- Connect the devices to be powered to the UPS output sockets.
- Switch the UPS on with the front button, then start the connected devices.
- Install PowerSoft on the computer and connect the USB cable when the installer asks for it.
The battery reaches full capacity after about a month on mains power. To use the full battery capacity, the manufacturer recommends discharging it three times with a load of about 100 W and recharging it fully.
Cleaning and storage
Disconnect the UPS from the mains before cleaning and do not use liquid or aerosol cleaners. Store the UPS upright in a cool, dry place with a fully charged battery. When stored at 0–30 °C, recharge the battery every 6 months, at 30–40 °C every 3 months.
In the box
- UPS EVER EASYLINE 650 AVR USB
- Quick start guide
- USB cable for connecting a computer, 1 pc