Description
The CyberPower UT650EG-FR is a line-interactive UPS rated at 650 VA, its apparent power in volt-amperes, and the maximum load of the connected devices is 360 W. In a power cut it switches the connected devices to battery within 4 ms.
Voltage correction by transformer is the core of a line-interactive UPS
A line-interactive UPS is an uninterruptible power supply that raises or lowers fluctuating mains voltage with a built-in transformer and only switches to battery when the voltage drops out or leaves the allowed range. On the UT650EG-FR this input voltage range is 165–290 V, within which automatic voltage regulation (AVR) evens out the voltage, and the output voltage is 230 V. An online UPS powers devices continuously through an inverter, the part that converts battery DC into AC, and suits servers or lab equipment, while a line-interactive model suits home computers and network devices.
Outlets, data line and indicators
The rear panel has three type E (earth pin) outlets, into which you plug a computer or other device with its own power plug. To protect a network or telephone line, connect the cable from the wall jack to the UPS IN jack and from the OUT jack on to the modem, computer, telephone or network device. On the front panel the green LED is lit in ECO mode and flashes while charging, the yellow LED is lit on battery and flashes when the battery is low, and the red LED is lit on a fault and flashes on overload. An audible alarm signals battery mode, low battery, overload and faults.
Charging and care
Charge the battery for at least 8 hours before first use so that it reaches full capacity; after that the sealed lead-acid battery (VRLA) recharges in 6 hours. Before servicing the battery or installing a computer component, turn the UPS off and unplug it from the mains.
In the box
- CyberPower UT650EG-FR UPS with fixed power cord
- Quick start guide




Reviews
There are no reviews yet.