Description
Handheld oscilloscope for signal and spectrum analysis
The two-channel handheld oscilloscope FNIRSI DPOS350P measures with a 350 MHz bandwidth and a 1 GSa/s sampling rate and also includes a signal generator and spectrum analyser, plus a frequency response analyser. You control every mode on the 7-inch 1024 × 600 pixel IPS touch screen; the housing measures 190 × 128 × 37 mm.

Oscilloscope mode with digital phosphor display
Rise time is 1 ns, the waveform capture rate 50,000 waveforms per second and memory depth 47 kpts. Bandwidth can be limited in hardware to 20 MHz or 150 MHz, and high-resolution mode raises resolution from 8 to 16 bits. In digital phosphor mode the more frequent signal parts appear brighter, and in colour temperature mode their colour shifts from blue to red. The device measures 12 parameters automatically, offers cursor measurement of time, period, frequency, level and voltage, and supports X-Y mode and time base zoom.


Function generator with 14 waveforms
The generator outputs 14 standard waveforms and stores up to 500 custom waveforms. Sine waves run from 0 to 50 MHz; the other waveforms reach 10, 5 or 3 MHz. Amplitude is 0–5 Vpp, offset −2.5 V to +2.5 V and duty cycle 0.1–99.9%, with 1 Hz frequency steps and 1 mV amplitude and offset steps.

Spectrum analyser and frequency response analysis
The spectrum analyser uses an FFT with a length of 4K to 32K and covers 200 kHz to 350 MHz at levels from −60 dBmV to +260 dBmV. A 2D and 3D waterfall view shows how the spectrum changes over time, and a cursor reads frequency and amplitude. The frequency response analyser outputs an excitation signal up to 50 MHz at 0–5 Vpp, measures at 20 to 500 frequency points and shows frequency, gain and phase with a cursor.


Storage, battery and charging
The memory holds 500 waveforms and 90 screenshots, which you can copy to a computer over USB. The built-in 3.7 V, 8000 mAh lithium battery gives about 3 hours of runtime and charges with a QC18W charger (12 V, 1.5 A). Power consumption is 10 W, and auto power-off can be set from 15 minutes to 1 hour or switched off. Firmware is updated with an ISO image.

Operation
With one key press, auto-set searches for signals on all active channels and fits them on the screen. Another key returns the zero level of all channels and the trigger position to their default. At start-up you can choose one of five presets.
In the box
- Oscilloscope FNIRSI DPOS350P, 1 pc
- 350 MHz probe, 2 pcs
- QC18W charger
- USB data cable
- Leads with alligator clips
- User manual