Description
Oscilloscope and signal generator in one portable device
The two-channel FNIRSI DS215H handheld oscilloscope measures signals with 50 MHz analogue bandwidth and a sampling rate of up to 250 MSa/s. It also has a built-in signal generator, so you can feed a test signal into a circuit and watch the response on the same screen.

Triggering, automatic measurements and signal analysis
Peak input voltage is up to ±400 V and the probe attenuation can be set to 1x or 10x. The trigger responds to a rising or falling edge, and the single trigger mode also captures non-periodic signals. Automatic measurement shows frequency, period, peak-to-peak voltage, maximum, minimum, mean and RMS values, amplitude, duty cycle and pulse width. The channel settings include FFT, and the menu offers cursors and X-Y mode as well as channel addition, subtraction, multiplication and division.

IPS screen, controls and screenshots
The 3.5-inch IPS screen with 480 × 320 resolution shows the waveforms and measurements of both channels at once. The device is operated with two rotary knobs and five buttons. A measurement view can be saved as a BMP image to the internal memory, and when connected to a computer over USB-C the device opens as a flash drive with the screenshots.

Built-in function generator with 13 waveforms
The generator waveforms include sine, square and sawtooth waves, DC, and exponentially rising and falling signals. Frequency can be set from 0 to 50 kHz in 1 Hz steps, amplitude from 0.1 to 3.0 V and duty cycle from 0 to 100%. The output is switched on and off with a short press of the run/pause button.

Use
The device switches on with a long press of the OK button, and at first start-up you choose one of eight menu languages with knob A. To measure, connect the probe ground clip to the circuit’s common ground and the probe tip to the signal source, then press the auto-set button and fine-tune the time base, vertical sensitivity and trigger. Auto power-off can be set to 15 minutes, 30 minutes or 1 hour.
Cleaning and care
Wipe the housing and screen once a month with a soft cloth, without alcohol, strong acids or alkalis. Store the device in a dry, ventilated place and charge the battery regularly so that it never fully discharges. To update the firmware, connect the device with a USB-C cable to a computer running Windows 10 or later.
In the box
- Oscilloscope FNIRSI DS215H, 1 pc
- oscilloscope probe
- test lead with crocodile clips
- USB-C cable
- BNC adapter
- user manual


Reviews
There are no reviews yet.